Troubleshooting
Troubleshooting
Problems are listed in the left column, and causes in the middle column. Solutions, along
with further manual references, are listed in the right column. If the problem(s) cannot be
solved after consulting this section and/or appropriate sections of this manual, call Orion
at (800) 333-6556.
Table 4-1. Troubleshooting Charts
PROBLEM
POSSIBLE CAUSE
SOLUTION
The Machine Will Not Start
•
A Program is not selected. The
machine will not start unless a pro-
gram is selected.
•
The E-stop button is pressed.
•
The carriage obstacle detect switch/
carriage door open switch located on
the bottom of the carriage is pressed.
•
Check that the Power On/ Off Switch
in the On position and power is prop-
erly plugged in.
•
See “Selecting a Program” on
page 3 - 9.
•
Release the E-stop button.
•
Ensure the bottom of the car-
riage is NOT pressing on any
obstructions. Ensure the car-
riage door is closed.
•
Plug in the machine. Turn the
Power On/ Off Switch to the
On Position to allow opera-
tion.
Turntable Will Not Turn
•
The turntable potentiometer knob is
set too low.
•
The carriage obstacle detect switch/
carriage door open switch located on
the bottom of the carriage is pressed.
•
Turn the turntable potentiome-
ter knob toward the (+) to
increase the speed.
•
Ensure the bottom of the car-
riage is NOT pressing on any
obstructions. Ensure the car-
riage door is closed.
Carriage Will Not Raise or
Lower
•
The carriage potentiometer knob is
set too low.
•
The carriage obstacle detect switch/
carriage door open switch located on
the bottom of the carriage is pressed.
•
Turn the carriage potentiome-
ter knob toward the (+) to
increase the speed.
•
Ensure the bottom of the car-
riage is NOT pressing on any
obstructions. Ensure the car-
riage door is closed.
The Machine Cycle Stops
•
The obstruction switch on the bottom
of the film carriage was tripped.
•
Remove the obstruction and
Restart the program.
The Carriage Stops Prior to the
Top of the Load
•
The photocell delay setting found on
the Top Wraps Modification Screen
is set too low.
•
Increase the photocell delay.