Introduction and Safety
Page 1-13
Inspection
1.
Remove all packing and supporting additions - these may include the blocks under the
carriage and the restraining bar over the table.
Note:
When removing the stretchwrap film covering the machine, care
must be taken not to cut any of the electrical wires and/ or polyure-
thane covering on the film carriage rollers.
2.
Perform a visual inspection of the electrical and mechanical parts for loosened joints
and / or broken connections. Any suspected shipping damage must be reported imme-
diately to the freight carrier. Any transport damage cannot be claimed to Orion Pack-
aging Inc.
Items that are vulnerable to damage and must be inspected are as follows:
•
Motors and transmissions
•
Junction boxes
•
Electrical conduits
•
Proximity and limit switches
•
Photocells
3.
Check around the tower to ensure that there is no crippling of the movable parts i.e.
casters, center axle or drive assembly.
4.
Verify the following:
•
Check wires and conduits for crushed sections or loose fittings.
•
Verify the film carriage to be sure that it is correctly aligned with the tower
•
Verify all there is no damage to the HMI and all buttons are in tact.
•
Use the panel access keys to open the panel or motor access doors. The Panel Access
Key part # is 735586.
Figure 1 - 5
Panel Access Key