Machine Manual
Orion
CTS Flex Stretchwrapper
Revision 3.0
System Operation
25 July 2016
Page 3-44
Flex Dashboard Remote Viewing
Setting up Dashboard Remote Viewing
Your new flex machine has the capability of remotely viewing the status from your com-
puter browser on the same network. You will need your network administrator to advise
what IP address should be used for your flex machine.
1.
Press Login to log into Admin level security.
2.
Enter the user password. Press Enter.
3.
Press Diagnostics.
4.
Press HMI.
5.
Enter the IP network settings approved by your system administrator.
6.
Press Save (Disk Icon.)
7.
On the back of the HMI, connect an ethernet cord to the Eth IF2 connector. Route to
your network router.
8.
On your computer bowser connected to the same network, enter the IP address you
assigned to the flex machine then /dashboard.asp.
9.
Example:
192.168.1.2/dashboard.asp
(Continued on Next Page)
Figure 3 - 33
Setting the IP
Address