21
Starting the Generator Remotely from the AC Panel - The remote start/stop, hour meter and blower
switch are all located on the starboard aft cabin wall next to the AC/DC panel.
When using your optional generator to provide power to the alternating current system, the slide
mechanism on the AC panel needs to be in the “Up” position in order to switch on the generator breaker.
•
At the remote control panel for the battery management system (installed on the
console), press the house battery switch forward to the on position
•
Go into the cabin, locate the AC/DC panel and move the generator toggle switch to the
on position.
•
Locate the blower switch installed next to the AC/DC panel and turn it on. After allowing
the blower to run for a few minutes and circulate fresh air throughout the bilge, the
generator can be started up.
•
Locate the generator start switch, which is next to the blower switch. Press the green
side in and hold it until the generator starts up. This may take a couple of attempts
depending on how much fuel is in the fuel tank and if the generator fuel hoses have been
previously run dry.
•
When the generator is running, the green light on the start switch will stay illuminated and
water will be coming out of the generator exhaust thru-hull on the outside of the hull.
•
To turn the generator off, press and hold the start switch to the right until the generator
stops running. Then turn off the blower.
The remote start/stop for the generator is equipped
with an hour meter at the top of the switch
Note: The manufacturer of the generator provides the limited warranty for the generator
and most associated parts. Please refer to their owner’s manual and follow their
recommendations for scheduled maintenance and service. To be in accordance with the
terms and conditions of their limited warranty, all service and/or warranty repairs must be
performed by a repair facility that is authorized to work on their equipment.
Please refer to the owner’s manual provided by the manufacturer of the generator for operational
procedures and for information related to the care and maintenance of their product. When in doubt,
always defer to the generator manufacturer’s instructions and/or recommendations.
Shore Power with Cord
Shore power (50 amp) is used for the operation of AC devices such as your
air conditioner, battery charger, and 110-volt outlets for other appliances.
The shore power package includes a 25 foot long yellow shore power cord.
Note: Before attempting to connect to shore power, take precautions to minimize contact
arcing by making sure that the AC main breaker switch is in the “Off” position prior to
plugging into shore power. The AC main breaker is located on the AC panel on the
starboard aft cabin wall.
Remote
Start/Stop for