When an error message is displayed (Error code list)
Maintenance/Troubleshooting
1-128
Errors displayed during online monitoring of the logic program
The following error messages are displayed when a logic program (project file) cannot be
transferred from the Display for the purpose of monitoring it on the PC side (during online
monitoring).
Errors displayed with ProjectCopy
Error Message
Cause and Solution
Reference
Failed to start Monitor.
The cables may not be connected or
the communication setting may be
wrong. Confirm that the cables are
connected properly. Select [Option
Settings] from the [View] menu and
check [Communication Settings] for
[Monitor Step].
)
GP-Pro EX Refer-
ence Manual
“5.14.7 [Prefer-
ences] Settings
Guide n Monitor
Step” (page 5-
153)
Error Message
Cause and Solution
Reference
Select project.
If you try to execute the copy operation
without selecting a project file, this
error message appears. Before execut-
ing the copy operation, select a project
file.
)
GP-Pro EX Refer-
ence Manual
“37.9.3 Project-
Copy(Copy Tool)
Settings Guide”
(page 37-164)
Project does not exist.
If you select a project file that does not
exist, this error message appears.
Check if the project file exists, and
select a project file again.
)
GP-Pro EX Refer-
ence Manual
“37.9.3 Project-
Copy(Copy Tool)
Settings Guide”
(page 37-164)
Copy destination not found.
If the folder for storing a project file is
not located in the specified directory,
this error message appears. The
WinGP folder configuration may have
been changed for some reason. Re-
install the WinGP folder.
)
GP-Pro EX Refer-
ence Manual
“37.3.2 Setup
Procedure n
Install/Uninstall”
(page 37-11)
Copying failed.
If the system failed in copy operation
for any reason, this error message
appears.
—
Unable to copy as connected
devices/PLCs are different.
If the type of connection device speci-
fied in a project to copy does not match
with the connection device driver of
WinGP, this error message appears.
Before copying the project, change the
type of the connection device, or trans-
fer the project by using a transfer tool.
)
Continued