Pro Co Sound Momentum md16ae Manual Download Page 1

1

 Momentum md16ae Manual

16x16 AES3/EBU Digital Interface

Manual

Pro Co Sound, Inc.

225 Parsons Street | Kalamazoo, MI 49007

1-888-253-7360 | www.procomomentum.com

md16ae

Summary of Contents for Momentum md16ae

Page 1: ...1 Momentum md16ae Manual 16x16 AES3 EBU Digital Interface Manual Pro Co Sound Inc 225 Parsons Street Kalamazoo MI 49007 1 888 253 7360 www procomomentum com md16ae...

Page 2: ...ntative or dealer must perform all warranty servicing of the units otherwise all aspects of this warranty are void 2 All tamper proof seals on the unit s must be intact in order for the unit s to be s...

Page 3: ...pper Wiring Copper Connection Fiber Connection Network Configurations Clock Configurations External Clock Momentum Clock AES3 Clock Setup Network Clock Sync Using the Control Panel Setting Device Star...

Page 4: ...shock do not expose any part of your Momentum System to rain or moisture To reduce the risk of electrical shock do not remove cover There are no user serviceable parts inside Refer servicing to servi...

Page 5: ...e in the successes and failures of our efforts Welcome to the Pro Co Family When receiving your Momentum System please check all cartons for damage If there is damage notify the shipper and dealer in...

Page 6: ...ide a platform that is as close to analog as possible without the inherent problems that are associated with traditional wiring Flexibility and expandability are enhanced through the use of modules fo...

Page 7: ...panel and 16 input output channels each with a signal clip LED indicator visible on the front panel The control panel includes a power LED status LED a 3 digit readout display and control buttons F1...

Page 8: ...t signal to noise ratio 2 4 3 1 External Clock Connection See below for pin out diagram Pin Out Diagram DB25 Pin Description 1 2 3 4 5 6 7 8 9 10 11 12 13 Digital Out 7 8 Ground Digital Out 5 6 Digita...

Page 9: ...This power supply comes with three jumper cables that will allow up to four units to be linked together and powered by one MUPS The MUPS is a separate option and must be ordered additionally Use a sta...

Page 10: ...T568B or equivalent connectors when wiring your system This view shows the color code as viewed from the front of the female socket or the rear of the male connector Crossover wiring is not needed th...

Page 11: ...are endless For more information on advanced configurations and support visit www procomomentum com For further support con tact you local dealer or Pro Co technical support One to One Connection CAT...

Page 12: ...ber Note Running both Fiber and CAT6 copper or two CAT6 copper connections can provide a redundant link between FOH and the Stage Ethernet Switches must be configured using Spanning Tree Protocol Mana...

Page 13: ...ntrol PC to multicast filtering Multicast MAC 01 15 AB C6 00 00 See Network Design White Papers mo8 Output Chn 001 mo8 Output Chn 009 Chn 017 Chn 025 Chn 033 Chn 041 mo8 Output mo8 Output mo8 Output m...

Page 14: ...r PC software Connect clock source output to the word clock input of the md16ae Set clock to match the applicable Momentum sample rate 48k or 96k When selected the locked clock LED should be green An...

Page 15: ...the network clock Additional Slave Device not an md16ae Overview of Momentum Network Clock Source If the Momentum Network clock is selected and transmitting channel 1 this unit is the clock master If...

Page 16: ...d 2 provides the clock source for the md16ae For a md16ae device to be set in AES3 clock source mode it must be set to transmit channels 1 16 Overview of AES3 Clock Source Only one md16ae can be set t...

Page 17: ...via the network Using the Control Panel F1 Mode Edit Decrease Value F2 Mode Select Increase Value Display Status Indicator Power Indicator Button LED Description F1 Mode Select F1 activates the edit m...

Page 18: ...rolled with a PC each Momentum unit will need a unique IP address All IPs need to be set manually on the individual unit It is best practice to keep the input unit s IP address sequential with its cha...

Page 19: ...ch function to edit and F1 activates the edit mode within that function Holding both F1 and F2 executes edit and exits edit mode The flow chart below displays each of the controlling F1 and F2 functio...

Page 20: ...by step guide are presented in the same order as the functions 1 on the unit s menu structure In order to edit a channel the user must first scroll to the function in need of editing select 2 the app...

Page 21: ...dr edit mode 3 Tap F1 to decrease value Press F2 to increase value Toggle F2 to select Clr to set the IP 4 to factory default of 192 168 1 1 Press and hold F1 and F2 to execute and save the change 5 T...

Page 22: ...k Output 3 3Vp p Impedance 75 ohms 70K ohms Jitter Attenuation Below AES3 Jitter Transfer Function Mask Network Specifications Standard Gigabit Ethernet Protocol Power Over Ethernet PoE 802 3af Compli...