background image

 

7

 
This is the normal operating procedure for the system. It indicates that a reanalysis of the battery status was initiated and 
after a series of steps the green LED will illuminate. 

 

 
 
 
 
LIGHT EMITTING DIODES (LED) FAULT CODE INDICATIONS  

 

The microprocessor is constantly monitoring the charger circuitry and will both detect and display blinking LED indications if a 
fault is detected.  The battery type LED will be 

OFF

 during a fault code condition.   

 
30% RED LED BLINKING .....................................................NO BATTERY DETECTED  
This indication occurs whenever the charger circuitry cannot detect a battery.  The charger circuitry will not allow charge 
current to flow under this condition.  With the AC power supply cord unplugged, check the connection to the batteries for 
proper polarity (black wire to negative or -).  Also check for corrosion free secure connections to the battery.  Please call 
technical support for further assistance (800.742.2740). 
 
30 & 60% RED BLINKING LEDS …………FORMING STAGE TIMEOUT SHUTDOWN  
This indication occurs if the battery voltage has not risen above 1.75 volts per cell within the first 3 hours of charging.  This 
indicates that a possible battery problem exists and that the charge cycle has been terminated at this point.  Please call 
technical support for further assistance (800.742.2740). 
 
30, 60 & 90% RED BLINKING LEDS ............................OVERALL TIMER SHUTDOWN  
This indication occurs if the charger has not completed the charge cycle within the allowable factory set time period.  This 
indicates that a possible battery problem exists and that the charge cycle has been terminated at this point.  Please call 
technical support for further assistance (800.742-2740). 
 
30, 60, 90% RED and 100% GREEN BLINKING LEDS…....................INTERNAL OVERTEMP SHUTDOWN  
This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are 
above factory specified levels.  This could indicate that a possible charger problem exists and that the charge cycle has been 
terminated.  Please call technical support for further assistance (800.742.2740). 
 
Note: Disconnecting and reconnecting the AC power supply cord will reset the charger. 

 
 

 

LIMITED WARRANTY 

 
Pro Charging Systems, LLC (PCS) makes this Limited Warranty only to the original retail purchaser.   
 
PCS warrants this battery charger for three years from the date of retail purchase against defective materials and/or 
workmanship.  If such defects should occur, this unit will either be repaired or replaced at the discretion of the manufacturer.  
It is the responsibility of the original purchaser to return the charger along with proof of purchase, transportation, and/or any 
mailing or handling charges prepaid to the manufacturer or its authorized representative. 
 
This limited warranty is void if the product is misused, improperly maintained, handled carelessly or incorrectly operated.  
Additionally, this warranty is void if the charger is disassembled, the charger’s charge cables are cut, the power cord is cut 
off, the charger is altered without authorization from PCS, the serial number is removed, or repair is attempted by anyone 
other than an authorized representative.   
 
PCS makes no other warranty other than this limited warranty and expressly excludes any implied warranty, including 
warranty for any incidental or consequential damages. 
 
This is the only expressed limited three year warranty authorized by PCS and does not authorize anyone to assume or make 
any other obligation towards the product other than this three year Limited Warranty.  Some states do not allow limitation of 
incidental or consequential damages. 
 

Summary of Contents for i2412

Page 1: ... and i4818 ________________________________________ 081808 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying AC power to your Pro Charging Systems PCS charger Contact technical support at PCS with any product installation or service questions 800 742 2740 Pro Charging Systems LLC LaVergne TN 37086 3539 ...

Page 2: ... Installation and Preparation Page 4 General Operation Pages 4 5 Charging Indications Page 6 Troubleshooting Page 6 LED Fault Code Indications Page 7 Limited Warranty Information Page 7 Additional Products Page 8 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for future reference...

Page 3: ...n Keep work area well lit 8 Do not overreach Keep proper footing and balance at all times Do not reach over or across electrical cables or frames 9 Avoid electrical shock To reduce risk of electrical shock unplug charger from outlet before attempting any maintenance or cleaning 10 Do not operate charger with damaged electrical cord or plug To reduce risk of damage to the electrical plug and cord p...

Page 4: ...pecified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without cell caps carefully follow manufacturer s recharging instructions Study all battery manufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge When using an extension cord make sure that pins on plug of extension cord are...

Page 5: ...st be stopped first disconnect the AC power supply cord from its outlet then disconnect the charger DC output plug from the battery receptacle We recommend that you leave your system plugged in This will reduce sulfation on the lead plates of the batteries and allow your PCS charging system to keep your batteries fully maintained and ready to perform at their best To reduce the risk of fire use on...

Page 6: ...batteries 3RD RED LED Charging Initial Charging Up To 30 3RD 4TH RED LEDS Charging 60 Complete 3RD 4TH 5TH RED LEDS Charging 90 Complete BLINKING GREEN LED Finishing Stage STEADY GREEN LED Charge Complete Monitoring Batteries The green LED is illuminated whenever the charge cycle has terminated and the internal circuitry has determined the batteries to be fully charged The green LED will blink dur...

Page 7: ...OVERTEMP SHUTDOWN This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are above factory specified levels This could indicate that a possible charger problem exists and that the charge cycle has been terminated Please call technical support for further assistance 800 742 2740 Note Disconnecting and reconnecting the AC power supply co...

Page 8: ...om state to state Please call Pro Charging Systems LLC for full warranty information and or service please call 800 742 2740 Below are some of our other options in chargers and battery accessories Call our technical support group for more detailed information or visit our web site www dualpro com ...

Reviews: