Page 1 of 2
11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
INSTALLATION INSTRUCTIONS
PZM-WWG1-#000K
SĒNIK
G1 GRAZE CCT WHITE
100-
240V
SAFETY INFORMATION
• Read all instructions before beginning. Save these instructions for future use.
• To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this
manual. Stay within its guidelines when using this product.
• All units must be unplugged before installing or servicing in any way.
• Do not route cords or units through walls, doors, windows, or any similar part of a
building structure.
• Do not use if there is any damage to the unit, its lens, and/or power cord
insulation. Inspect periodically.
• Do not submerge in water or other liquids.
• Secure unit(s) using mounting hardware appropriate for the mounting surface. Do
not secure unit or power cord with staples, nails, or other sharp items that may
damage insulation.
• As dictated by engineer’s drawings or local code, install safety cables on fixtures.
• Do not attempt to open or service the fixture. No parts are serviceable by the user.
• Do not exceed the specified voltage and current input. See Figure 1.
• This product has a polarized grounded plug as a safety feature to reduce the risk
of electric shock. Do not cut the plug off or alter it in any way.
• The operating temperature range of PZM-WWG fixtures is -20°C (-4°F) ~ 45° (113°F).
• Do not exceed the maximum number of fixtures in any single run. See Figure 1.
• For cleaning, use a soft, dry or damp cloth. Do not use harsh chemicals
or abrasives.
These products may represent a possible shock or
fire hazard if improperly installed or attached in any
way. Products should be installed in accordance with
these instructions, current electrical codes, and/or the
current National Electric Code (NEC).
When using this product outdoors, basic safety
precautions should always be followed to reduce the
risk of fire, electric shock and personal injury including
the following:
• Ground Fault Circuit Interrupter (GFCI) protection
should be provided on the circuit(s) or outlet(s) to
be used for outdoor use. Receptacles are available
having built-in GFCI protection for this measure of
safety.
• Use only outdoor extension cords, such as type
SEW, SEOW, SEOOW, SOW, SOOW, STW, STOW,
STOOW, SJEW, SJEOW, SJEOOW, SJTW, SJTOW, or
SJTOOW. This designation is marked in the wire of
the extension cord. Never use with an extension cord
unless plug can be fully inserted.
WARNING
WARNING
FIGURE 1
Prizm
™
is a trademark of American Lighting, Inc. ©2018 www.PrizmLighting.com REV1842
Item
PZM-WWG1-#000K
Input Voltage Range
100-240V AC, 50/60Hz
Max Power
23.8W
Power Factor
0.98
Input Current
0.2443A
Drive Current
1.5A
Max Power Linking
38 units
Max Signal Linking
30 Units (using PZM-WW-SIGADAPT-BK)
BEFORE INSTALLATION:
1. Familiarize yourself with the dimensions and key aspects of the wall washer. See FIGURE 1.
Determine the number of fixtures to be used and how power will be delivered. Each fixture has a 5pin grounded power and signal
combination cord which must either be linked to a power + signal splitter (PZM-WW-PSL-BK for the first wall washer in a series), another wall
washer fixture, or terminated with a terminator end cap (PZM-WW-SIGEND). Available accessories (sold separately) include an XLR3 to XLR5
adapter (PZM-WW-XLR3-XLR5), a 10ft XLR3 signal extension cable (PZM-WW-XLR3-10-BK), various power jumper cables in 1ft, 3ft, 6ft,
and 20ft lengths (PZM-WW-JUMP#-BK), as well as a signal only linking cable (PZM-WW-SIGADAPT-BK).
2. Determine mounting method and fasteners required. See FIGURE 2. A pole clamp with safety cable is also available (PZM-WW-PCLMP
sold separately).
3. Determine method of control.
Each fixture is factory set to ID = 001. A remote device management (RDM) device is required to address units
as anything other than 001.
FIGURE 1
FIGURE 2
Attached mounting
brackets
180
°
Tilt/Angle
Adjustment
Power + Signal In
Power + Signal Out