Assembly
Page EN-18
Installing the flue screen
(6)
1. Screw the wall bracket for the upper flue
screen (6) into the prepared wall plugs
using 2 round-head screws (10).
(2)
(3)
2. Push the upper part (2) of the flue screen
halfway into the lower part (3) of the flue
screen.
2x
(7)
(3)
(8)
3. Place the retaining plate (7) onto the low-
er flue screen (3) so that it lines up with
the chamfers on the inside. (Screws and
elongated holes should point upwards).
4. Turn two plate screws (8) from the outside
through the retaining plate (7) and the
lower flue screen (3). Tighten the screws
somewhat, but only loosely.
2x
(8)
5. Place the entire flue screen onto the ex-
haust hood, with the closed side of the
flue screen facing forward.
6. Screw the lower part (3) of the flue screen
with 2 plate screws (8) to the sides of the
exhaust hood (1).
7. For exhaust air operation only: Insert the
exhaust air hose (4) into the connection
at the wall break (hose end with 150 mm
diameter).