Fault Messages
313
INVALID COMMAND
No
Printer detects
twinax protocol
communication
errors.
The printer reports the
error; host action is
required.
LO DRV. SHORT *
No
Circuit(s) on the
hammer bank or in
the hammer bank
power cable
shorted to ground.
Contact your authorized
service representative.
1
LOAD PAPER
Yes
Printer is out of
paper.
Load paper.
ONLINE
CU TIMED OUT
Yes
Enable poll
timeout. The
printer was not
enabled for one
minute. (Coax
interface)
Check cable connection
and host system.
ONLINE
28 CU NOT ENAB
Yes
Poll timeout error.
The printer was not
polled for one
minute. (Coax
interface.)
Check cable connection
and host system.
ONLINE
8344 FAILED*
No
Link-level code test
detects hardware
failure.
Contact your authorized
service representative.
1
P00 ERROR:
SYSTEM FAULT*
No
Unexpected
interruption
occurred.
Cycle power to see if the
message clears, if not,
contact your authorized
service representative.
1
PAP BAD TABLE*
No
Fatal firmware
error on controller
board.
Contact your authorized
service representative.
1
Table 17. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation
Solution
Summary of Contents for P5005B
Page 10: ...Table of Contents 10...
Page 18: ...Chapter 1 Printer Overview 18...
Page 62: ...Chapter 2 Set The Top Of Form 62...
Page 88: ...Chapter 3 Operational Procedures 88...
Page 296: ...Chapter 5 RS 232 And RS 422 Serial Interfaces 296...
Page 336: ...Appendix C 336...
Page 340: ...Appendix D Federal Communications Commission FCC Statement 340...
Page 365: ......