8. Alignment
IMPORTANT: The ODV2D-V2 unit comes with a protective cover over the glass to protect from finger prints. Be
sure to remove it before starting the calibration process. Failure to do this will result in failure
during the calibration. Make sure the glass is clean before proceeding.
About Alignment
There are four inter-dependent mechanical adjustments that affect the alignment and calibration of the ODV2D: Height,
Tilt, Slope and Center-Line. They need to be set in the order shown.
The Height is factory set and should not need adjustment. Tilt and Slope are set independently, but may affect each other
(as one is changed, the other may move too) requiring an iterative adjustment. The Center-Line adjustment is done last.
Alignment Web Page
1. From ODV2D-V2 Dashboard, select Field Calibration.
NOTE:
You may select which style ODV2D or ODV2D-V2 to be installed. The default web page is for the ODV2D-V2.
These installation instructions are for the ODV2D-V2 version. If you are installing an ODV2D, follow the on-screen
instructions for alignment and calibration.
Figure 29:
Web Browser “
ODV2D-V2
Dashboard”