22
Comm Error
ODV-2D > Control > Comm Error
This menu allows the ‘Validator not communicating’ error to be clearable by
the user or not clearable by the user.
Not Clearable
The user must resolve the error and recycle the printer
power to print.
Clearable
The user will be able to clear the fault and print jobs.
Barcodes in these jobs will not be validated.
Factory Default
Clearable
Comm Timeout
ODV-2D > Control > Skip Labels
This option is used to control the threshold of time the validator does not
respond with verification status before declaring an error.
Minimum
10 seconds
Maximum
180 seconds
Factory Default
25 seconds
IMPORTANT
For labels with complex and significant data en-
coded in 2D barcodes, this menu may need to be
increased.
Symbology Submenu
Several ODV-2D options which define which barcodes will be graded and which will be ignored. This can
be chosen based on symbology or orientation. Note there are also PTX-SETUP commands that can be
used to configure these options as described in Section “
Orientation
ODV-2D > Symbology > Orientation
This menu selects the barcode orientations that will be processed and
graded and which will be ignored.
All
All orientations will be graded.
Picket
Picket barcodes and 2-D barcodes in 0 and 180 de-
gree rotations.
Ladder
Ladder barcodes and 2-D barcodes in 90 and 270
degree rotations.
Factory Default
All