Page 1: ...DOC 040 2350 PCB901 Rotating Half Rail Instructions REV 001 The information in this document is subject to change without notice Page1 ...

Page 2: ...ure 10 C 50 C 14 F 122 F environment Relative humidity range 10 93 Maximum patient weight safe working load This device is not intended to support the entire weight of a patient This device has been tested to allow a downward load of 750 N 168 lbf and a side load of 500 N 112 lbf Description of device function This device has a single upright locked position When the upright locked position is not...

Page 3: ... pending hazards that if not avoided will result in immediate serious personal injury or death in addition to damage of the equipment WARNING Information that appears under the WARNING description concerns the protection of personnel from possible hazards that can result in injury or death in addition to damage of the equipment CAUTION Information that appears under the CAUTION description concern...

Page 4: ... bed frame WARNING This device rotates When routing cables from other equipment in the medical bed precautions shall be taken to avoid squeezing those between parts of the medical bed WARNING No modification of this equipment is allowed WARNING Do NOT use assist bars as handles for moving the bed WARNING Keep all moving parts free of obstructions WARNING NEVER allow anyone under the bed at any tim...

Page 5: ...en evaluated When these specialty mattresses or mattress overlays are used the end use facility must take steps to ensure that the therapeutic benefit outweighs the risk of entrapment ASSIST RAIL WARNING Other manufacturers assist rails bars may not be compatible and can lead to entrapment issues or harm to patients Only compatible Primus Medical assist bars and rails may be used on this bed Make ...

Page 6: ...notice Page6 4 Insert the 3 8 x2 5 square neck bolts from the outside of the bed frame and install the knobs on the ends of the bolts WARNING The knobs must be installed tightly to ensure proper mounting of the device 5 Repeat the procedure for the opposite side Assist bar mounting positions and orientations Head deck only ...

Page 7: ...HIS DEVICE IS NOT COMPATIBLE WITH WASHDOWN TUNNELS Inspections WARNING Failure to take care of your device may decrease the life of your product and increase maintenance Always inspect and service the device at the required intervals INITIAL INSPECTION Inspect All Components Check components for obvious damage Verify proper function Quarterly Maintenance Check Inspect all welds for cracks Ensure p...

Page 8: ...DOC 040 2350 PCB901 Rotating Half Rail Instructions REV 001 The information in this document is subject to change without notice Page8 ...