70276001
9
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
Section 3
Troubleshooting
IMPORTANT: Refer to appropriate wiring diagram for aid in testing tumbler components.
1. MOTOR DOES NOT START
POSSIBLE CAUSE
TO CORRECT
Electrical power off, circuit breaker tripped or
blown control fuse.
• Check service to tumbler.
• Check primary and secondary fuses.
Inoperative transformer.
• Replace transformer.
Loading door not closed or inoperative door switch. • Close door or test switch and replace if inoperative.
Lint panel switch not closing.
• Test lint panel switch, replace if inoperative.
Trunnion bearings binding.
• Replace trunnion bearings.
Start circuit not completed.
• Press start switch or test switch and replace if inoperative.
Idler bearings binding.
• Replace bearings.
Inoperative motor.
• Have motor tested and replace if inoperative.
Inoperative relay.
• Replace relay.
Timer improperly set.
• Turn drying timer clockwise to desired setting.
Inoperative timer.
• Test timer and replace if inoperative.
Broken, loose or incorrect wiring.
• Refer to wiring diagram located on back of tumbler or in
literature packet.