nstruction    

 

 

 

 

Code/RefNr.:

 

525927 / 525928 

Date:

 

18 Sep 2008 

Subject:

 

Install an AC-reactor on FS16/23/33/40/55, RS27/35 

 

Suitable for all versions except FS40/55 3x200-240V 

 
 
 
 

 

 

 

 

Primus Belgium 

 

Driemasten 126 

B-8560 Gullegem 

Belgium

 

Phone: +32 (0)56 43 52 00 

Fax:     +32 (0)56 40 34 63 

E-mail: 

[email protected]

 

Web: www.primuslaundry.com 

 

 

 

Primus Central Europe

 

Mistecká 1116 
742 58, Příbor 

Czech Republic

 

Phone:+420 556 768 800 

Fax:    +420 556 723 383 

E-mail: 

[email protected]

 

Web: www.primuslaundry.com

 

 

 

 

Primus France

 

Rue Jacques Monod z.i. Est 

F-69120 Vaulx-en-Velin 

France

 

Phone:+33 (0)4 78 79 55 75 

Fax:    +33 (0)4 72 04 62 72 

E-mail: 

[email protected]

 

Web: www.primuslaundry.com

 

 

         WARNING:

    

 

  Carry  out  the  handling  according  to  the  following  manufacturers 

instructions. 

  Always respect warnings from the relevant manuals of the machine. 

  Make  sure  all  electric  power  or  other  energy  sources  are  disconnected 

and closed before any servicing. Always switch off the main switch. 

  Wait 10 minutes after electrical power is disconnected to eliminate power 

on the inverter terminals. 

  Installation, maintenance and service must be executed by skilled service 

personnel only or by a service organisation with appropriate authorization 
from the manufacturer. 

  For service, use only original replacement parts. 

  Re-install all machine parts in the original way. 

  The  qualified  agency  performing  this work  assumes  all  responsibility  for 

this kit installation. Other service activities than described below, disable 
all manufacturers responsibility. 

 

Make  sure  children  are  not  around  during  work  in  progress.

 

 

 

 

 

www.groupdynamics-laundry.com 

[email protected]

Summary of Contents for 40

Page 1: ...NG Carry out the handling according to the following manufacturers instructions Always respect warnings from the relevant manuals of the machine Make sure all electric power or other energy sources are disconnected and closed before any servicing Always switch off the main switch Wait 10 minutes after electrical power is disconnected to eliminate power on the inverter terminals Installation mainte...

Page 2: ...er Ironer General Chasis Shock absorbers Cabinet Controler Coin unit Electric components sensors Heating unit Inlet Soap hopper Motor pulley belts Bearing house seals Drum Door Drain General Chasis Cabinet Controler Coin unit Electric components sensors Heating unit Motor pulley belts Bearing house seals Drum Door Air filter Air fan Exhaust General Chasis Cabinet Controler Coin unit Electric compo...

Page 3: ...Needed tools 2 Wrenches M13 For 1 ph inverter Wires 2 5mm length 50cm 4Pc preferably blue and black For 3 ph inverter FS16 23 FS33 400V RS27 35 Wires 2 5mm length 50cm 6Pc preferably black For 3 ph inverter FS33 200V FS40 FS55 Wires 4mm length 50cm 6Pc preferably black Drill Ø10mm for metal Wire cutting and wire stripping pliers 3 Part numbers Nr part number description Quantity 525927 H616 SERVIC...

Page 4: ...h inverter 3x380 480V without N only Since there is used a transformer for the control circuit it is not possible to mount the AC reactor in the contactor box Therefor mount the AC reactor on the rear bridge beside the water valves Drill 4 holes diam 10mm and fix the AC reactor with the included bolts and nuts Make sure that no burs from the drilling can enter the frequency inverter or other compo...

Page 5: ...525928 Instruction AC reactor FS16 55 RS27 35 P5 15 Make the electrical connection according the scheme and instructions below www groupdynamics laundry com sales groupdynamics lv ...

Page 6: ...to terminals U1 and V1 of the AC reactor 3 ph inverter Connect these wires to terminals U1 V1 and W1 of the AC reactor 1 ph inverter Connect terminals U2 and V2 to the inverter contactor by new wires to the same terminals where you have disconnected the 2 other wires Terminals W1 and W2 of the AC reactor will not be used if the inverter is 1 phase 3 ph inverter Connect terminals U2 V2 W2 to the in...

Page 7: ...the AC reactor on top of the box of the frequency inverter Drill 4 holes diam 10mm and fix the AC reactor with the included bolts and nuts Make sure that no burs from the drilling can enter the frequency inverter or other components www groupdynamics laundry com sales groupdynamics lv ...

Page 8: ...525928 Instruction AC reactor FS16 55 RS27 35 P8 15 Make the electrical connection according the scheme and instructions below www groupdynamics laundry com sales groupdynamics lv ...

Page 9: ... AC reactor 3 ph inverter Connect these wires to terminals U1 V1 and W1 of the AC reactor 1 ph inverter Connect terminals U2 and V2 to the inverter contactor by new wires to the same terminals where you have disconnected the 2 other wires Terminals W1 and W2 of the AC reactor will not be used if the inverter is 1 phase 3 ph inverter Connect terminals U2 V2 W2 to the inverter contactor by new wires...

Page 10: ...ctor on a suitable place in the electrical box at the back of the machine Drill 4 holes diam 10mm and fix the AC reactor with the included bolts and nuts Make sure that no burs from the drilling can enter the frequency inverter or other components www groupdynamics laundry com sales groupdynamics lv ...

Page 11: ...525928 Instruction AC reactor FS16 55 RS27 35 P11 15 Make the electrical connection according the scheme and instructions below www groupdynamics laundry com sales groupdynamics lv ...

Page 12: ...U1 V1 and W1 of the AC reactor You migth have to replace the original wires by longer ones Connect terminals U2 V2 W2 to the inverter contactor input side by new wires to the same terminals where you have disconnected the 3 other wires Make sure to attach and connect all wirings so that they can not be damaged by vibrations www groupdynamics laundry com sales groupdynamics lv ...

Page 13: ... the corner of the back panel but it has the small disadvantage that you always need to disconnect the wires if you want to open the back panel Drill 4 holes diam 10mm and fix the AC reactor with the included bolts and nuts Make sure that no burs from the drilling can enter the frequency inverter or other components www groupdynamics laundry com sales groupdynamics lv ...

Page 14: ...525928 Instruction AC reactor FS16 55 RS27 35 P14 15 Make the electrical connection according the scheme and instructions below www groupdynamics laundry com sales groupdynamics lv ...

Page 15: ...and W2 of the AC reactor will not be used if the inverter is 1 phase 3 ph inverter Connect terminals U2 V2 W2 to the inverter contactor by new wires to the same terminals where you have disconnected the 3 other wires Make sure to attach and connect all wirings so that they can not be damaged 5 Remarks If you have a machine with a transformer for the control circuit this transformer fulfills the sa...