Primex Wireless, Inc.  

Manual Part No.: Q12354-INST 040512 

 

XR Electric Analog Clock 

This instruction sheet provides the installation instructions for XR Electric Analog Clock models. It is recommended to 
read the Analog Clock User Guide for detailed safety precautions, and installation and maintenance procedures.  

Electric Model Power Specifications 

Model 

Current 

Draw 

Cord Specifications 

Line 

Neutral 

Ground (Earth) 

24 VAC* 

21mA 

18” (45.72cm) pigtail/hardwired 

Yellow 

Yellow 

 

120 VAC* 

25mA 

18” (45.72cm) standard non-polarized two-prong plug 

Black 

White 

Green 

240 VAC**  67mA 

18” (45.72cm) BSI 1363 plug 

Brown 

Blue 

Green with yellow stripe 

* Available in US/Canada only  

** Available in UK only

 

Installation Requirements 

Before installing an analog clock, verify your system’s transmitter is operating properly and sending a signal with 
adequate building coverage (refer to the manual accompanying the transmitter). Clocks are required to be installed at a 
location within adequate transmission range of the transmitter. 
The backs of most analog clocks feature two specially designed Clock-Lock hangers spaced at precise distances, one 
on the top, and the other on the bottom. The hole spacing dimensions are listed below. 

Clock Size 

Hole Spacing 

Clock-Lock Feature 

12.5” (31.75cm)  

9” (22.86cm) 

Yes 

16” (40.64cm)  

9” (22.86cm) 

Yes 

Installation Procedures 

Pluggable Surface Receptacle (Figure 1) 

The power cord is wrapped around the two posts on the back of the clock and can be unwrapped or wrapped to the 
desired length. The power cord is to be routed through the strain relief and exit the bottom of the clock through the exit 
slot away from the upper portion of the clock’s antenna to maintain optimal reception. The excess cord can be wound 
around the two cord posts.  

Pluggable Recessed Receptacle Optional Installation 120 VAC Model Only (Figure 2)

 

The receptacle may be behind the clock (with excess cord wound around the two cord posts). To assure that the cord 
does not prevent the clock from resting flush against the wall, the center of the recessed receptacle should be located 
about 2.5” (6.35cm) to the right of the clock’s center. 

Pigtail/Hardwired Configuration Only 

Please be sure to leave a minimum of 6” (15.24cm) of cord inside the junction box. To conform to UL and National 
Building Code, the use of the Clock-Lock feature is required for this configuration. 

Self Initialization 

After the power supply is applied, the clock’s receiver automatically begins to step through all channels rapidly, normally 
taking 1 second to 20 seconds, scanning for a valid time signal from the transmitter. When the time displayed matches 
the time displayed on the transmitter, the clock is ready for normal operation.