![Primes HP-MSM-HB Original Instructions Manual Download Page 78](http://html1.mh-extra.com/html/primes/hp-msm-hb/hp-msm-hb_original-instructions-manual_1601727078.webp)
78
Revision 00 EN - 01/2021
HP-MSM-HB
35,0(6
20
Technical data
HP-MSM-HB
HP-MSM-HB
20 kW
Characteristics Measurement
Max. medium power
Singlemode
Multimode
5 kW
10 kW
10 kW
20 kW
Beam Diameter
20 µm... 1000 µm
Wavelength Range
1000 nm...1100 nm
Admissible wavelength range of the laser
light
1025 nm- 1080 nm
Admissible measuring range
±
3z
R
Design wavelength
1064 nm
Magnification
4,5
Max. input-NA
0,11
Max. Energy Density on the 1. optical
surface at 10 ns
on request
Max. Energy Density on the 1. optical
surface (cw-mode)
on request
Max. movement range
120 mm
40 mm
Max. movement range with fiber bridge
Supply data
Supply voltage, DC
24 V
±
5 %
Max. current consuption
1,8 A
in standby mode
0,4 A
Min. Cooling water flow rate.
0,7 l/min/kW
Cooling water temperature Tin
dew-point temperature < T
in
< 30 °C
Maximum water inlet pressure
< 5 bar
4 bar... 5 bar
Compressed Air Pressure
0,5 bar to 1,0 bar
Maximum Pressure
2 bar
Specification of compressed air according
to ISO 8573-1: 2010
6:4:4
Communication
Ethernet
100 Mbit/s
PRIMES-Bus (RS485)
Safety circuit (Interlock)
Measures and Weight
L x W x H (without cables and plugs)
600 x 401 x 388
727 x 400 x 385
Weight, approx.
35 kg
42 kg
Ambient Conditions
Service Temperature Range
+15 °C ... +40 °C
Storage Temperature Range
+5 °C ... +50 °C
Reference Temperature
+ 22 °C
Admissible Relative Air Humidity (non-
condensing)
80 %