![Primes HP-MSM-HB Original Instructions Manual Download Page 74](http://html1.mh-extra.com/html/primes/hp-msm-hb/hp-msm-hb_original-instructions-manual_1601727074.webp)
74
Revision 00 EN - 01/2021
HP-MSM-HB
35,0(6
17.2
Draining the cooling circuit of the HP-MSM-HB
The cooling circuit of the HP-MSM-HB must be completely drained. Storage or transport at a temperature
that is close to or below freezing can lead to damages due to the formation of ice, if the cooling circuit is not
completely empty.
X
Drain the cooling circuit completely.
You may use compressed air to purge the cooling
circuit of the HP-MSM-HB.
Cooling Circuit Connectors
17.3
Sealing the cooling circuit of the HP-MSM-HB
Even if the cooling circuit has been drained completely, a small amount of residual water remains inside the
device. This water could escape during transport and could damage the electronics of the device.
X
Seal the connecting plugs of the cooling circuit
by using of the enclosed plugs.
A total of 4 plugs with 12 mm outer diameter are
required.
1
2
3
4