![PRIMERGY BX620 S3 User Manual Download Page 169](http://html1.mh-extra.com/html/primergy/bx620-s3/bx620-s3_user-manual_1601716169.webp)
169
PRIMERGY BX620 S3 Server Blade User’s Guide
6
Hi
gh Rel
iabi
lity
T
o
ols
●
Voltage Monitoring
ServerView monitors the voltage. In an environment where ServerView is not applied, voltage
irregularities cannot be detected during operation. In order to detect the problem, the server must reboot
to run the BIOS Setup Utility or the Server Management Tools. As leaving the voltage surges, the server
may malfunction or data loss may occur.
●
Power Supply Monitoring
ServerView monitors the power supply. In an environment where ServerView is not applied, power
supply irregularities cannot be detected during operation. In order to detect the problem, the server must
reboot to run the BIOS Setup Utility or the Server Management Tools. System stops due to power supply
failures cannot be prevented.
6.2.1 Installing ServerView
●
When Installed Using ServerStart
If the OS is installed using ServerStart, ServerView will be installed at once with the OS and other high
reliability tools.
●
When Installed Manually (Linux)
ServerView cannot be installed using ServerStart. To install ServerView manually into a Linux system,
refer to "Installing" in "ServerView User’s Guide".
Be sure to install SNMP service before installing ServerView.
■
When an error screen appears after ServerView installation
(Windows Server 2003 only)
If Windows Server 2003 Service Pack 1 is applied, the following message may appear on restarting after
installing/uninstalling ServerView.
There is no problem with operations. Click [Close Message] to close the message.
In order to protect the computer, this program is terminated by
Windows.
Name: SNMP Service
Summary of Contents for BX620 S3
Page 30: ...30 Chapter 1 Overview ...
Page 164: ...164 Chapter 5 Operations after OS Installation ...
Page 172: ...172 Chapter 6 High Reliability Tools ...
Page 238: ...238 Chapter 8 Hardware Configuration Utilities ...
Page 276: ...276 Chapter 9 Operation and Maintenance ...