![PRIMERGY BX620 S2 User Manual Download Page 276](http://html.mh-extra.com/html/primergy/bx620-s2/bx620-s2_user-manual_1601715276.webp)
276
Chapter 9 Operation and Maintenance
9.10Maintenance & Notes
This section explains the details of the maintenance & Notes.
9.10.1 Hard Disk Failure is Detected
If hard disk failure is detected during POST, the BX620 S2 Server Blade onboard SCSI array controller
stops with the following message.
If the controller stops with this message, insert the floppy disk "OnBoard RAID Utility" into the floppy
disk drive, and press [Ctrl] key + [A] key at once to start up the system from the floppy disk. The utility
automatically starts up. The following message appears on the utility.
As shown here, if the message "Fatal ERROR happened. Please call support engineer." appears:
Do not start up the system. Please contact an office listed in "Contact Information" of "Start Guide" and
system administrator.
If the message "OK. You can boot system. Please check HDD status after boot." appears:
Remove the defective hard disk following the procedures below.
Warning!: The array is degraded. Press [Ctrl] [A] to continue after
insert Floppy Disk.
Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 0
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
curState: 1 prvState: 0
Previous Physical Disk States:
ID0 : Failed ID1 : Failed
Current Physical Disk States:
ID0 : Online ID1: Failed
Background command progress status for controller 0...
IR Volume 1
Current operation : None
Volume ID : 0
Volume status : Enabled
Volume state : Degraded
Physical disk I/Os : Not quiesced
curState: 1 prvState: 3
Previous Physical Disk States:
ID0 : Online ID1 : Failed
Current Physical Disk States:
ID0 : Online ID1: Failed
OK. You can boot system.
Please check HDD status after boot
Summary of Contents for BX620 S2
Page 28: ...28 Chapter 1 Overview ...
Page 44: ...44 Chapter 2 Checking before OS Installation ...
Page 162: ...162 Chapter 5 Operations after OS Installation ...
Page 288: ...288 ...