178
Chapter 7 Installing Internal Options
■
Notes on Installing Memory Modules
●
Identifying Memory Modules
Make sure to install a pair of DIMMs, each having the same capacity. Check that the number beginning
with "CA" (e.g., CA05946-E101) printed on the label is same on the two DIMMs. Be sure to use a pair
of modules with the same number.
If the DIMMs have identification labels, be sure to install a pair of DIMMs with the same capacity with
the label placed on the same location.
The figure below shows the identification label locations.
Place pin 1 (circled part in the above figure) on the left to identify the label locations. Identification
labels are applied onto a DIMM in the following patterns.
A: Label applied
-: Label not applied
7.4.3 How to Install / Remove Memory Module
This section explains how to install and remove memory modules.
1
Turn off the server blade.
→
"3.3 Turning Off the Server" in "BX600 S2 Blade Server System Unit Hardware Guide"
2
Touch a metal part of the chassis to discharge static electricity.
3
Remove the server blade from the chassis to install a memory module.
→
"4.2 Installing Server Blade" in "BX600 S2 Blade Server System Unit Hardware Guide"
table: Memory identification label
Pattern
Identification label A
Identification label B
Identification label C
1
-
-
-
2
A
-
-
3
-
A
-
4
-
-
A
5
A
A
-
6
A
-
A
7
-
A
A
8
A
A
A
Identification label A
Identification label B
Identification label C
1