89
PRIMERGY BX600 Management Blade Hardware Guide
❑
: Parameter
• System Fan (1_3_3_2)
Displays and sets the lifetime of the system fan.
Parameter
Setting
Contents
1. System Fan Fail Reaction
❑
continue
❑
shutdown-and-
poweroff
Sets the action for each fan.
• continue
Sets operations to continue even during a fan failure.
• shutdown-and-poweroff
Performs graceful shutdown of the main power supply
of the chassis when a fan error occurs.
When using refer to "6.2 Points to Note about Remote
Power OFF and the Shutdown Function" (
System Fan Designation
-
Displays the location of each fan.
• Rear1,2-Fan-1 – 2
System fan unit internal fan
• PowerUnit1,2,3,4-Fan-1 – 3
PSU internal fan
(1: power cooling fan, 2 and 3: rear system fan unit)
System Fan Status
-
Displays the status of each fan.
System Fan Current Speed
-
Displays the current rpm of each fan.
System Nominal Maximum Speed
-
Displays the nominal maximum speed of each fan.
System Current Maximum Speed
-
Displays the maximum speed of each fan.
Parameter
Contents
System Fan_1 – System Fan_4
The settings for running time and display of a specific fan can be displayed by
selecting that system fan number.
"• 2. System Fans Live Time Table (1_3_3_2_1)" (p.90)
+------------------------------------------+
| |
+------------------------------------------+
System Fan (REAR Fans) page_1_3_3_2
(1) System Fan_1
(2) System Fan_2
(3) System Fan_3
(4) System Fan_4
Enter selection or type (0) to quit: