115
PRIMERGY BX600 Management Blade Hardware Guide
■
Event Log (1_8)
Checks event logs related to Management Blades and Server Blades.
❑
: Parameter
❍
: Setting at time of purchase
Parameter
Setting
Contents
1. Manage Blade Event Log
-
Checks the log of the Management Blade.
2. Server Blade Event Log Table
-
Checks the logs of the Server Blades installed in the
chassis.
2. Server Blade Event Log Table" (p.116)
3. Server Blade Power On/Off
Event Log Enable
❑
enable
❑
disable
This is set whether power ON/OFF and shutdown of the
Server Blade is recorded in a Management Blade event
log.
Important:
If set to "enable", the number of event logs
registered increases. Pay attention to the
remaining number of event logs and make
sure not to exceed the maximum.
4. Management Blade Wrap
Around Event Log Enable
❍
enable
❑
disable
Sets the log operations when the number of Management
Blade event logs has maximized.
• enable
When the number of event logs has maximized, logs
are overwritten in order from the oldest.
• disable
Stops log operations when the number of event logs
has maximized.
Event Log page_1_8
(1) Management Blade Event Log
(2) Server Blade Event Log Table
(3) Server Blade Power On/Off Event Log Enable : disable
(4) Management Blade Wrap Around Event Log Enable : enable
Enter selection or type (0) to quit:
+------------------------------------------+
| |
+------------------------------------------+