Connecting the BladeFrame BF200 to a Power Source
Release 5.0
4-5
Powering on the BladeFrame BF200
This section describes how to power on the BladeFrame BF200.
After the BladeFrame BF200 is powered on, do not power it off
unless it is being moved or serviced.
BladeFrame
BF200 Power
Distribution
The BladeFrame BF200 power system is available with either a
20-amp or 30-amp spine. The 30-amp option is available for
systems running full configurations of the higher end 4-way
pBlades, which draw more power than 2-way pBlades.
and
list the electrical specifications for both
options.
Table 4.3 Electrical Specifications — 20-Amp BladeFrame
BF200
Parameter
Description
Rating/Value
Input Voltage
Voltage range
200 - 240 VAC, auto-ranging
Input Frequency
AC input power
frequency range
47 - 63 HZ, single-phase
Input Current
Maximum current
rating
16 amps RMS at 200/208/230 volts
Power
Consumption
System power
range
930 watts minimum to 3200 watts
maximum (varies with
configuration)
BTU Rating
System total
3175 BTU/hour minimum to
10,926 BTU/hour maximum
(varies with configuration)
Connector Type
North America
NEMA L6-20P
Connector Type
International
IEC 309 - 16 Amp