Configure APS6 Module(s) for Luminaires:
Lamp power for a luminaire is provided by an APS6™ power
supply module installed in a Series 300™ Modular Rack.
CAUTION:
Do not change mode or power setting with power applied
to module.
Step 1. At face of APS6 module(s), set rotary power switch to 625W -
Position 1 (
).
Step 2. Set mode switch to PSET for manual operation.
Step 3. Apply power to lamp by moving circuit breaker switch to the ON position.
Note:
The PSET (Preset) mode enables manual control of the module. This is the normal mode of
operation. The DCV (Dimmer Control Voltage) mode operates the module with 0-10Vdc control input.
This mode is only required when using an SPC-36 controller to remotely control modules from a
console. Refer to the Series 300™ Modular Rack Service Manual (02.9640.0010) for more
information.
Figure 2-12: APS6 Module
Power Up the Luminaire:
“Powering Up the Luminaire” on page 30
for further operating instructions.
PRG
PRG
ARC
7257730
MODULE
BREAKER IS OFF
BEFORE
SELECTING POWER.
OFF BEFORE REM
WARNING:UNIT MU URNED
DO NOT UNPLUG H
ENSURE THAT
O
O
A
S300U-06
DCV
PSET
DCV
SHORT
STATUS
IPRES
MODE
3-XXXW
O
2-700W
1-625W
0-400W
POWER
3
1
2
APS 6
DCV
HORT
DCV
PSET
AC
ON
0-400W
2-700W
1-625W
3-XXXW
0
POWER
23
1
AC
ON
0
Power Switch
Mode Switch
Circuit Breaker Switch
Summary of Contents for VL5+
Page 1: ...USER MANUAL 02 9634 0002 VL5 Wash Luminaire VL5Arc Wash Luminaire ...
Page 10: ...VL5 SERIES WASH LUMINAIRE USER MANUAL viii 02 9634 0002 Notes ...
Page 24: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 14 02 9634 0002 Notes ...
Page 60: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 50 02 9634 0002 Notes ...
Page 72: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 62 02 9634 0002 Notes ...
Page 73: ...02 9634 0002 63 APPENDIX A Technical Specifications ...
Page 76: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 66 02 9634 0002 Notes ...
Page 82: ...VL5 SERIES WASH LUMINAIRE USER MANUAL 72 02 9634 0002 Notes ...