Sneak Operation
Sneak values are entered using the [Sneak] button and either the Timing Filter
or
Function Filter screen. After the
sneak operation has been defined, pressing the Timing Filter’s
ENTER
button or the Function Filter’s
TO CUE
button will cause all selected luminaires to move into the new position as defined by the values. The values are
entered numerically at the keypad.
Perform a sneak action using current timing information:
Step
1. Select channels as required.
Step
2. Bring up either Timing Filter
or
Function Filter screen.
Step
3. Select parameter to be changed.
Step
4. At keypad, press [Sneak] and enter required value, press [Enter].
Step
5. At filter, select next parameter and enter its value using keypad.
Step
6. When finished, press Timing Filter’s
ENTER
button
or
Function Filter’s
TO CUE
button. Selected
luminaires will move into the new position as defined by the values.
Sneak to a preset (same for color and beam):
Step
1. Select channels as required.
Step
2. Bring up either Timing Filter
or
Function Filter screen.
Step
3. Select parameter to be changed.
Step
4. At keypad, press [Sneak] [Preset] [x] [Enter] (where x is the discrete preset number)
or
press and hold
[Sneak] while pressing
Preset Palette Button
.
Step
5. Press Timing Filter’s
ENTER
button
or
Function Filter’s
TO CUE
button. Selected luminaires will move
into the new position as defined by the preset data.
To Sneak Cue data:
Step
1. Select channels as required.
Step
2. Bring up either Timing Filter
or
Function Filter screen.
Step
3. Select parameter to be changed.
Step
4. At keypad, press [Sneak] [Cue] [x] [Enter] (where x is discrete cue number).
Step
5. Press Timing Filter’s
ENTER
button
or
Function Filter’s
TO CUE
button. Selected luminaires will move to
the cue selected.
Note:
Cue numbers with decimals can be entered into sneak. For example, [Sneak] [Cue] [1] [.] [3] [Enter] will enter
Cue 1.3 into the selected parameter. Even cues without a decimal value will be displayed as a decimal value (1 is
1.00).
Note:
Sneak cue data will recall data only for the selected parameters from the given cue, which can be used as a
selective recall tool.
Perform a sneak action using new timing information:
Step
1. Select channels as required.
Step
2. Bring up either Timing Filter
or
Function Filter screen.
Step
3. Select parameter to be changed.
Step
4. At keypad, press [Sneak] and enter required value, press [Enter].
Step
5. To enter time, press [Sneak] [Time] and time value. Press [Enter].
Step
6. Press Timing Filter’s
ENTER
button
or
Function Filter’s
TO CUE
button. Selected luminaires will move to
their new values using their time settings.
Summary of Contents for V476
Page 1: ...SOFTWARE VERSION 3 5 WWW PRG COM V676 CONTROL CONSOLE V476 CONTROL CONSOLE USER MANUAL...
Page 18: ...XVI V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 22: ...4 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 46: ...28 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 88: ...70 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 124: ...106 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 142: ...124 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 178: ...160 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 208: ...190 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 344: ...326 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 358: ...340 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 390: ...372 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 412: ...394 V676 V476 CONTROL CONSOLE USER MANUAL Notes...
Page 413: ...B REFERENCE FRONT PANEL AND KEYBOARD SHORTCUTS PRE PROGRAMMED CANNED FEATURES GLOSSARY...
Page 433: ...C INDEX...