background image

Safety Instructions

13

EN

Areas of responsibility
Responsibilities of the person in 

charge of the instrument:

•  To understand the safety instructions 

on the product and the instructions in 

the User Manual.

•  To be familiar with local safety 

regulations relating to accident 

prevention.

•  Always prevent access to the product 

by unauthorised personnel.

Electromagnetic Compatibility 

(EMC)

WARNING

The device conforms to the most 

stringent requirements of the relevant 

standards and regulations. However, 

the possibility of causing interference 

in other devices cannot be totally 

excluded.

This equipment has been tested and 

found to comply with the limits for a Class 

B digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to 

provide reasonable protection against 

harmful interference in a residential 

instal-lation.This equipment generates, 

uses and can radiate radio frequency 

energy and, if not installed and used in 

accordance with the instructions, may 

cause harmful interference to radio 

communications.

However, there is no guarantee that 

inter-ference will not occur in a particular 

instal-lation. If this equipment does cause 

harmful interference to radio or television 

reception, which can be determined by 

turning the equipment off and on, the user 

is encouraged to try to correct the 

interference by one or more of the 

following measures:

•  Reorient or relocate the receiving 

antenna.

•  Increase the separation between the 

equipment and receiver.

•  Connect the equipment into an outlet 

on a circuit different from that to which 

the receiver is connected.

•  Consult the dealer or an experienced 

radio/TV technician for help.

Prexiso P100LCU

FCC statement (applicable in U.S.)

Summary of Contents for P100LCU

Page 1: ...IMPORTANT Read before Using P100LCU LASER DISTANCE MEASURE www prexiso eu com 2 WARRANTY LIMITED YEARS FUNC ...

Page 2: ...Clear Addition Subtraction Angle Measurement Memory Bluetooth Bluetooth Connection and Operation Brightness 4 4 4 5 5 6 7 8 8 9 9 10 10 Technical Data Message Codes Care Disposal 11 11 11 11 Safety Instructions Warranty Symbols used Permitted use Prohibited use Hazards in use Limits of use Areas of responsibility Electromagnetic Compatibility EMC FCC statement applicable in U S Laser classificatio...

Page 3: ...e that all users understand these directions and adhere to them Display Insert batteries i Change batteries when battery symbol is empty Prexiso P100LCU 2 EN FUNC On Measure Continuous measuring Units Measuring Reference Add Sub Bluetooth Area Volume Pythagoras Brightness Memory Clear Off Color Display Battery Units Main line Info Measuring Reference Memory Bluetooth Area Volume Pythagoras 88 8 30...

Page 4: ...the instructions in section Message Codes Example Unit setting Switch between the following units Prexiso P100LCU CLEAR OFF Change the measurement reference 1 2 The system default measurements start at the bottom as a reference point Press button to change the reference to middle for measurement 3 Press button to change the reference to top for measurement 0 000 m 0 00 1 16 0 1 16 in 0 00 ft ...

Page 5: ...t gloss surfaces Against dark surfaces the measuring time increases Continuous measuring 3 sec 1 2 The largest and smallest measured value appear above it Stops continuous measuring Press button to start the mode selected 4 3 Modes 2 1 Prexiso P100LCU Aim active laser at target Press button to select mode clockwise Press button to select mode counterclockwise min max 59 99 7 16 max59 99 7 16 min19...

Page 6: ...Aim laser at second target point 24 352 ft2 5 i The result is shown in the main line and the measured distance above i Note 1 The system default measurement start at the single distance measuring 2 Bluetooth and Brightness are inside of the ICON 3 The selection of specific Pythagoras Bluetooth Brightness and etc is the same way of modes seletion by clockwise or counterclockwise 5 EN ...

Page 7: ...aser at second target point Perpen dicular to the measuring surface 90 4 Aim laser at third target point 5 The result is shown in the main line and the measured distance above Aim laser at first target point Aim laser at second target point Pythagoras 90 1 2 3 4 The result is shown in the main line and the measured distance above 90 59 99 7 16 59 99 7 16 6 EN ...

Page 8: ...wn in the main line and the measured distance and angle above 59 99 7 16 90 Pythagoras 1 2 Aim laser at first target point 3 Aim laser at second target point 4 Aim laser at third target point Perpendicular to the measuring surface 5 The result is shown in the main line and the measured distance above 59 99 7 16 90 90 α α 88 8 EN 7 ...

Page 9: ...n once to add or press button twice to subtract next measurement from the previous data or EN Prexiso P100LCU 8 The result is shown at the top of the screen Range 0 360 4x90 Inclination measurement is used to measure a slope or incline e g stairs railings when fitting furniture laying pipes etc Angle Measurement 1 2 ON 3 40 8 º 36 0 º 59 99 7 16 79 99 7 16 20 00 39 99 7 16 ...

Page 10: ...es which have PREXISO app installed in advance i Search PREXISO app on App Store or Google Play Store select and download the app EN 9 30 88 8 59 99 7 16 59 99 7 16 2 30 88 8 59 99 7 16 59 99 7 16 Bluetooth Install PREXISO app 1 Up towards the memory Down towards the memory Step 1 and Step 2 are all available for the following buttons 2 ...

Page 11: ... and the Bluetooth Open the PREXISO app on your mobile device Click the ICON in the top right corner of the app to follow the User Guide for operation Bluetooth Connection and Operation FUNC i To select different brightness of the screen Brightness 1 2 3 OR ...

Page 12: ... appropriately in accordance with the national regulations in force in your country Adhere to the national and country specific regulations Product specific treatment and waste management can be downloaded from our homepage General Range 0 09 100 m 0 29 330 ft Measuring accuracy 2 mm 3 32 in Smallest unit displayed 1 mm 1 16 in Laser class Laser type Degree of Protection Autom power switch off Con...

Page 13: ...t Use of accessories from other manufacturers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Deliberate or irresponsible behaviour on scaffolding when using ladders when measuring near machines which are running or near parts of machines or installations which are unprotec...

Page 14: ...provide reasonable protection against harmful interference in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inter ference will not occur in a particular instal lation If this equipment does cau...

Page 15: ...his contact your dealer This warranty is void if product is used for commercial purposes This warranty is not transferable and does not cover products damaged by misuse neglect accident alterations or use and maintenance other than that specified in the owner s manual This warranty does not apply to any expendable parts that can wear from normal use This warranty excludes any accessories Labelling...

Reviews: