2.0 - Installation
2.1 - Mechanical Installation
DMY-2030-TOT
Light
Indicator and Totalizer front panel has 1/8 DIN size
(48 X 96 mm).
It is fixed by the rails which press it against the back side of the panel.
After preparing a 45 X 92 mm cut in the panel, remove the rails from the
Indicator and slide its rear through the cut until its front reaches the panel. Place the
rails again in the Indicator from the back of the panel and tighten the screws as
shown in figure 2.
Fig. 2 - Dimensional drawing, panel cutout and side view.
2.2 - Electrical Installation
DMY-2030-TOT
Light
Indicator and Totalizer may be powered by voltage
between 90 and 240VAC or 130 to 340VDC, any polarity. Remember that the
internal circuit is powered whenever the instrument is connected to the external
power supply.
Input and output signals must be connected to the instrument only when it is
turned off.