9 Black w Blue trace Wire:
Pulsed Ground Output Before Start
The Black w/ Blue Trace wire will provide a 1 second 300 mA pulsed ground output 500mS before GWR
becomes active as well as when the transmitter is used to disarm the system. Typical use for this output
would be to disarm a factory theft deterrent system to prevent false triggering of the factory alarm when the
remote start unit engages or when the system is used to unlock the doors. This will also activate when the
transmitter is used to disarm/unlock the system
NOTE:
This output can be selected to operate like the door unlock output as set in alarm feature setting
#1 by selecting feature #19 in Bank 3 for 2 Chirps or any other pulse timing shown for that feature
selection.
10 Black w/ Light Green trace Wire:
Pulsed Ground Output After Start
The Black w/ Light Green Trace wire will provide a 1 second 300mA pulsed ground output after the vehicle
is started under control of the remote start unit. Typically this wire will be used to re-lock the vehicle doors
if the doors unlock automatically when the factory anti-theft system is disarmed. This wire will also activate
when the transmitter is used to arm/lock the system. This output can be selected to operate in a number of
different configurations as shown in selectable feature # 21 of Bank 3.
11 LT. Blue Wire:
Ground Output While Running (-) 300mA
This wire provides a 300mA ground output that becomes active 1.5 seconds before the Remote Start
Unit initializes and remains grounded while running plus an additional 2 seconds after the Remote Start
Unit turns off. In all of the applications described below, a relay will be required.
The Light Blue wire can be used to accommodate the situations found on the following page.
12Gray w/ Black trace Wire:
Negative Inhibit Input / Trigger When Armed
The Gray w/ Black Trace wire provides an instant shutdown for the Remote Start Control Module whenever
it is grounded. Connect the Gray w/ Black trace wire to the hood pin switch previously installed. This wire
must be routed through a grommet in the firewall and connected to the hood pin switch. If connecting to a
factory hood pin switch, or separate alarm it is recommended that a double diode circuit be used to prevent
feed back of one device to the other.