The output adapter can have up to 9 outputs of different
diameters. Number and sizes of connectors must be specified at
time of order.
If necessary, adapter can include rotameters for
controlling volume of delivered air on each output.
Each case has a one hose running directly to the Machine. Hose splitters can be used if more outputs
are needed.
SENSOR CONNECTION
Digital RHT sensor supplied with Mini One XL is built inside brass housing Ø 9/32”.
Cable can be up to 120 meters long. Preservatech supplies a standard 10 meter long
sensor unless otherwise specified by client.
If for any reason client wants to use their own cable it must be a shielded, 4 twisted pairs
CAT 5 communication cable.
If possible the sensor should be located in the case closest to the machine this will ensure
the humidity deviations are minimal. In this configuration the machine reacts faster for
changes in ambient conditions therefore humidity inside the cases is balanced.