background image

 

Hot Water Ta nk: 

 

Power : 420W 

The Water Te mperatue : 

90

 

Hot Water Ta nk Material : SUS304 

Hot Water Ta nk Capacity : 5.0L/hour 

Te mperature Control : Double Bimetallic Thermostat (Chinaware) 

Cooling System: 

Theory  :  The  compressor  changes  the  refrigerant  between  liquid  and 

vapour ,and let the water and refrigerator cool . 

 6

Summary of Contents for pwc215t

Page 1: ...PREMIUM SERVICE Service Manual Water Dispenser Model PWC215T 1...

Page 2: ...ry disconnect power before servicing this product If electrical power is required for diagnosis or test purpose disconnect the power immediately after performing the necessary checks RECAPITULATING Th...

Page 3: ...PARTS LIST AND EXPLODE VIEW 3...

Page 4: ...4...

Page 5: ...CIRCUIT DIAGRAM FUNCTION Heating System Theory The stainless steel heater is directly touched with the water in the hot tank and let the water hot Heating Diagram 5...

Page 6: ...ot Water Tank Material SUS304 Hot Water Tank Capacity 5 0L hour Temperature Control Double Bimetallic Thermostat Chinaware Cooling System Theory The compressor changes the refrigerant between liquid a...

Page 7: ...Parts View System Data Power 75W 130W The Water Temperatue 10 Cold Water Tank Material SUS304 Cold Water Tank Capacity 2 0L hour 7...

Page 8: ...ng system block Refrigerant leakage 4 No c o l d w a t e r compressor cooling Compressor badness Repair it by maintain center Cold water use much Wait for a moment and use Temperature higher than norm...

Page 9: ...leakage Repair it by manufacture center 11 Cooling system goes on working Thermostat invalidation Adjust or replace it 12 Heating system goes on working Temperature controller invalidation Replace it...

Page 10: ...ect the hot tank with power 2 Test the thermostat with the multimeter and estimate the possible cause If the thermostat works the multimeter will appear data or beep Contrarily then contrary 3 Use the...

Page 11: ...working situation the compressor is proved normal by its quiver 2 Disconnect the PTC Starter cover and replace it 3 Check the compressor through the terminal Normal The resistance amount data is not m...