background image

 

User’s Manual

 

 

 

1.

 

Sound, the refrigerant flows inside the cooler. 

2.

 

Compressor and condenser become hot. 

3.

 

If the ambient humidity is high, there may be dewdrop on the surface, please use soft and dry 

cloth to clean in time. 

 

Summary of Contents for PRF1257DX

Page 1: ...Model Modelo PRF65DX PRF90DX PRF125DX PRF155DX PRF657DX PRF907DX PRF1257DX PRF1557DX SINGLE DOOR MERCHANDISER REFRIGERATOR VITRINA REFRIGERADOR COMERCIAL DE UNA PUERTA...

Page 2: ...t safety instructions 3 II Transportation and Placement 5 Product Features 6 Operation of the Temperature control knob 7 Electrical Connection 8 Caution for Safety 8 Caution for Using 9 Cleaning of th...

Page 3: ...nnected from its power source during cleaning or maintenance and when replacing parts 8 The A weighted emission sound pressure level is below 70Db A 9 Do not store explosive substances such as aerosol...

Page 4: ...2 22 65 15 2 10 8 3 25 60 16 7 12 0 4 30 55 20 0 14 8 6 27 75 21 1 15 8 5 40 40 23 9 18 8 7 35 75 30 0 27 3 NOTE the water vapor mass in dry air is one of the main points influencing the performance...

Page 5: ...do not expose it to rain Note schematic diagram for demand size of product space Choosing the installation location The unit is for indoor application only Due to the fact that the unit has a glass d...

Page 6: ...o insufficient drainage of the condensates Tilt unit by 2 angle for easy closing of door and drain Do not insert cream or spray bottles inside the cooler Do not store explosive substances such as aero...

Page 7: ...645 575 610 1710 615 610 1990 655 705 1990 Net Capacity L 189 239 339 439 Temperature 0 10 0 10 0 10 0 10 Control System Mechanical Mechanical Mechanical Mechanical Lock Light Yes Yes Yes Yes Refriger...

Page 8: ...e appliance Use of an extension cord can negatively affect the performance of the unit 4 Improper use of the grounded plug can result in the risk of electrical shock If the power cord is damaged have...

Page 9: ...ce and the inside of the cooler should be dry and clean Long term moisture will cause the cooler rust slowly There will be some stains on the surface 6 Periodical cleaning is suggested for your refere...

Page 10: ...fected Take out part of the storage Leakage of refrigerant Repair at a qualified service center Temperature is too low inside the cabinet Thermostat does not work properly Check the thermostat Change...

Page 11: ...anual 1 Sound the refrigerant flows inside the cooler 2 Compressor and condenser become hot 3 If the ambient humidity is high there may be dewdrop on the surface please use soft and dry cloth to clean...

Page 12: ...User s Manual www premiumlevella com...

Reviews: