reaches 5.8 to 6 Vdc.
If the static battery voltage will not charge to and remain at 5.8 - 6 Vdc:
1. While pedaling the bike, make sure the battery charging voltage is greater than 6 Vdc
(7.5 Vdc max). Access the console service test menu, select the
BAT VOLT
para-
meter to read the battery charging voltage, see
2. Stop pedaling the bike and verify that the battery voltage remains ≥ 5.8 Vdc. If not,
replace the battery. If the battery does not remain ≥ 5.5 Vdc after a few hours with no
pedaling, replace the battery
Battery Fuse
The inline battery fuse is part of the battery assembly cable red wire connected to the bat-
tery positive terminal. To remove the fuse, open the fuse holder by twisting the fuse holder
top cap and removing the fuse.
Fuse specification: Inline fuse, 5 amp/250 Vdc
Procedure
Review entire procedure before starting.
Removal procedure
1. Remove the front and rear belt guard covers, see
"Belt Guard Cover Replacement"
2. Determine the battery condition, see
"Determining the battery condition" on the pre-
.
3. Carefully disconnect the battery cable Black wire from the Negative (-) battery ter-
minal and then the Red wire from the Positive (+) battery terminal. Disconnect the bat-
tery Negative (-) terminal wire first:
Contact Precor Customer Support at [email protected] or 800.786.8404 with
any questions.
Page 44
5 Replacement Procedures
Battery Replacement