The brake system consists of a variable power supply with an output voltage based on the resistance level
selected by the user. The voltage is applied to an electromagnet that is mounted to the generator frame,
and produces an eddy current breaking force applied to the flywheel of the generator.
1. Connect a DC voltmeter to the wired terminals of the electromagnet using clip leads, and dress
the leads out the back of the unit so as not to interfere with the motion of the crankarms.
2.
Pedal the unit (to supply power) and place the unit in the “Hardware Validation” service mode
(Reset 5,1,7,6,5,7,6,1). Run the “Brake Test” and press resistance “UP” ▲ until the unit is at
resistance level 7.
3. The voltmeter should read between 10 and 20 VDC depending on how fast you are pedaling.
4. If no voltage is present, either the variable power supply on the lower control module is bad (no
output from the lower control module) or there is an open in the electromagnet.
Troubleshooting the Lift System
Lift System Description:
Summary of Contents for AMT12 base
Page 250: ......
Page 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Page 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Page 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Page 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Page 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Page 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Page 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...