3 Check the generator belt tension, if not within specification continue with the following adjustment steps.
See
Drive Belt Gauge Instructions
.
Generator Belt Tension Specification
Generator Belt
Tension
new
85 +/- 5 lbs (38.6 +/- 2.3 kgs)
used*
60 - 75 lbs (27.2 - 34 kgs)
Note: * More than 1 hour of use.
4 Loosen or tighten the generator adjustment nut and bolt until the belt gauge reads approximately 90 lbs.
5 Tighten the generator mounting bolts.
6 Select the QUICKSTART program and adjust the resistance up
▲ key until resistance level 10 is
displayed. Pedal the AMT for approximately one minute and then recheck the belt tension.
7
Recheck the drive input belt and the generator belt tension, readjust if out-
of-spec. See
Drive Belt Gauge Instructions
.
FIGURE 253: GENERATOR
Summary of Contents for AMT12 base
Page 250: ......
Page 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Page 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Page 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Page 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Page 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Page 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Page 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...