Replacing the Drive Input Pulley
Procedure
1 Remove the covers as per procedure,
Cover Replacement
(on page 53).
2 Remove the tension from the inner flat belt pulleys by lifting up on the stairarms, pulling the flat belts off
the flat belt pulleys, and then gently setting the stairarm down.
FIGURE 162: GENERATOR
3 Loosen the two bolts that secure the step up pulley mounting bracket bolts to the frame.
4 Loosen the adjustment bolt for the step up pulley until tension has been removed from the input pulley
belt and it can be removed from the pulleys.