2- Operation Verification
This section provides you with a quick method of checking the AMT operation. Check the AMT operation at
the end of a maintenance procedure and when it is necessary to ensure that the AMT is operating properly.
Verification Procedure
1 Pedal the AMT to apply power, or use the optional external power supply.
2 Press and hold the reset key for at least 6 seconds, if errors are present the error log will be displayed.
Make note of all the errors in the error log and odometer reading for which the error occurred. The
odometer in the error log can help you determine age and relevance of the error. Once the errors have
been written down, the error log can be cleared.
3 Enter the
Hardware Validation
test by entering
Diagnostic
mode as follows:
Press either the STOP, PAUSE or RESET buttons and then enter
5,1,7,6,5,7,6,1
Select and run the Display Test, then the Keypad Test, then the Heart Rate Test and verify
results. (LEDs light, Keys all function, Heart rate is acquired and displayed)
Enter the Machine Tests (submenu) and run the Brake test and the Incline test and verify results.
(Resistance is smooth and is controlled from resistance level 1 to resistance level 20, Lift (if
applicable) goes up and down and the A/D value changes smoothly throughout the range)
Press the reset or back key to exit diagnostics.
4 Operate the AMT in the Manual program. Adjust the resistance to level 7. Operate the AMT for at least
1 minute while pedaling the unit.
a) Concentrate on the feel of the motion and the sound of the input drive assembly. Be on the alert for
unusual noises or vibrations.
b)
Observe the LED’s on the electronic console. Make sure that each LED lights as the information
corresponding to that LED is displayed on the electronic console.
5 If the unit is equipped with a variable step height (Open Stride), press the INCLINE key while viewing
the electronic console. Pedal the unit and confirm that the step height increases and the incline display
increments to level 5 as the INCLINE key is continually being pressed.
6 If the unit is equipped with a variable step height (Open Stride), press the INCLINE
key while viewing
the electronic console. Pedal the unit and confirm that the step height increases and the incline display
decrements to level 1 as the INCLINE
key is pressed.
7 Press and hold the reset key for at least 6 seconds, to look at the error log again. This time look for any
NEW errors displayed resulting from the verification test indicating that the unit needs attention.
Summary of Contents for AMT12 base
Page 250: ......
Page 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Page 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Page 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Page 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Page 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Page 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Page 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...