Page 47
2
Bad lower control module
Possible Remedies
1
This error would typically happen when the lift was already in motion (typically downward) when a
lift command in the opposite direction (lift up) was issued.
2
Some motors exhibited a very long turnaround time and the lift motor would still be moving in the
original direction (downward) while the control system was attempting to move the lift in the
opposite direction.
3
If the error 45 condition is persistent, replace the lift motor.
4
This is a very rare condition, if the lift moves in the opposite direction of the issued lift command,
replace the lower control module.
Error 46
– Low Battery Voltage (Open Stride AMT12
only)
Description:
The operating system has a battery monitoring system. If the battery voltage falls below 11 VDC when
stride height movement is initiated or the battery voltage falls below 10 VDC after the ramp movement has
been initiated, ramp movement will be stopped and the message ERROR 46 will be displayed. Stride
Height motion will not be enabled until such time as the battery voltage exceeds the above limits. The
battery voltage must be raised to correct this condition either by battery charging or battery replacement.
This is strictly a battery problem and not an incline system or incline motor problem.
Possible Causes:
1. Open fuse in fuse on the positive battery wire (Open Stride AMT12 only).
2. Faulty or poor connection on the battery or LPCA.
3. Low or no voltage output from battery.
Possible Remedies:
1. Remove power from the unit and remove the lift fuse from the in line fuse holder on the positive
battery cable. Measure the fuse with an ohmmeter, the fuse should read approximately 1 ohm or
less. If the ohmmeter reading is significantly high, replace the fuse. If the fuse is open, please
refer to #2 below before you continue.
2. Check battery cable connector for shorts or poor connections.
3. Enter the diagnostic program per procedure, P80 Settings or Accessing the P30 Diagnostic
Software. Using the diagnostic program allows you to test the incline system without continuously
Summary of Contents for AMT12 base
Page 250: ......
Page 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Page 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Page 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Page 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Page 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Page 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Page 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...