Possible Causes
1
Poor or intermittent connection in the lift position sensor (potentiometer).
2
Bad lift position sensor
3
Bad lower control module.
Possible Remedies
1
This is the most common cause of an error 44. Verify all wiring and connections associated with
the lift position potentiometer. Repair or replace wiring or connections as appropriate. Because of
the nature of the revolution sensor an error 44 is rarely associated with it.
2
Operate the lift in the diagnostics while monitoring the lift position number being displayed. If the
reading is erratic and makes large changes in readings the lift position potentiometer is probably
bad. Replace the lift motor.
3
If there is actual lift motion without a manual or program control lift command having been issued,
replace the lower control module.
Error 45 - Lift Moving in Wrong Direction
Description
The lift control system has detected that the lift is moving in the opposite direction of the issued lift command.
Possible Causes
1
Lift Motor hysteresis.
Summary of Contents for AMT12 base
Page 250: ......
Page 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Page 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Page 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Page 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Page 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Page 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Page 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...