Note:
There must be a reason for the lift motor to be out of calibration, therefore simply re-calibrating
the lift motor will often not fix the problem.
3
If the lift calibration number (A/D value) is not 0 or 255 and does not increment when the lift motor
moves, replace the lift motor.
If you have performed all of the procedures above and have been unable to correct the problem, search
for solutions in the service bulletins or call Precor customer service.
Error 44 - Un-commanded Lift Motion
Description
The lift control system has detected that the lift is in motion without a lift command having been issued. This
can happen in one of two ways: either the lift drive circuit has failed in a turned on condition or the lift position
sensor (lift position potentiometer or revolution sensor) is sending an erroneous signal to the lift control
circuit.
Summary of Contents for AMT12 base
Page 250: ......
Page 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Page 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Page 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Page 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Page 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Page 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Page 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...