© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 261
12 Check the generator belt tension, if not within specification continue with the following adjustment steps.
See
Drive Belt Gauge Instructions
.
Generator Belt Tension Specification
Generator Belt
Tension
new
85 +/- 5 lbs (38.6 +/- 2.3 kgs)
used*
60 - 75 lbs (27.2 - 34 kgs)
Note: * More than 1 hour of use.
13 Loosen or tighten the 1/4-20 X 3 generator adjustment nut and bolt until the belt gauge reads
approximately 90 lbs.
Summary of Contents for AMT12 base