FIGURE 188: GENERATOR BELT
29 The belt gauge should read approximately 90
±
10 lbs. If the belt tension is significantly high or low the
belt tension may be adjusted by loosening or tightening the generator mounting adjustment bolt. See
Drive Belt Gauge Instructions
(on page 265)
30 Loosen or tighten the generator adjustment nut and bolt until the belt gauge reads approximately 90 lbs.
See
Drive Belt Gauge Instructions
(on page 265)
31 Tighten the two bolts that secure the generator mounting bracket to the frame. Torque to 160 inch
pounds
32 Lift the stairarms and then thread the flat belts over the flat belt pulleys.