12 Replace the lower PCA and battery bracket and connect the cables as per procedure,
Replacing the
Lower PCA and Battery Bracket
(on page 164).
13 Replace the lower PCA cover as per procedure,
Lower PCA Cover
(see "
14 Replace the covers as per procedure, Cover
Replacement
(on page 53).
Replacing the Drive Input Pulley Belt
Drive Input Pulley Belt Replacement Procedure
1 Remove the covers as per procedure,
Cover Replacement
(on page 53).
2 Remove the tension from the inner flat belt pulleys by lifting up on the stairarms, pulling the flat belts off
the flat belt pulleys, and then gently setting down the stairarm.
3 Loosen the generator mounting bolts.
4 Loosen the generator adjustment bolt until the top of the bracket slots are resting on the generator
mounting bolts.
5 Loosen the step up pulley mounting bolts.
6 Loosen the step up pulley adjustment bolt until tension has been removed from the input pulley belt and
has sufficient slack so that the belt may be removed from the step up pulley.
7 Remove the drive input belt from the step up pulley and discard.
Summary of Contents for AMT12 base
Page 250: ......
Page 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Page 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Page 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Page 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Page 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Page 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Page 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...