© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
Page 170
2 Remove the lower PCA cover as per procedure,
Lower PCA Cover
(see "
3 Disconnect the cables from the lower PCA and then remove the lower PCA and battery bracket as per
procedure,
Replacing the Lower PCA and Battery Bracket
(on page 164).
4 Remove the generator tension adjustment bolt, washer, lock nut and tension plate.
5 Loosen the two generator mounting bolts and nuts, remove the generator belt from the generator pulley.
6 Remove the two generator mounting bolts and remove generator.
7 Secure the replacement generator using the two generator mounting bolts removed in the previous step,
do not fully tighten at this time.
8 Replace the tension plate in the mounting slot in the generator.
9 Thread the tension bolt and washer through the frame mount bracket and generator tension plate, then
fasten the washer and lock nut to the tension mounting bolt.
10 Replace the generator belt over the generator pulley.
FIGURE 152: GENERATOR
11 Adjust the Input and Generator pulley tension. Go to "Inspecting and Adjusting the Generator Belt
Tension" procedure.
FIGURE 153: GENERATOR
Summary of Contents for AMT12 base
Page 250: ......
Page 254: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 254 ...
Page 270: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 270 ...
Page 272: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 272 ...
Page 273: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 273 ...
Page 274: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 274 ...
Page 275: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 275 ...
Page 276: ... Precor Incorporated Unauthorized Reproduction and Distribution Prohibited by Law Page 276 ...