PrecisionTemp RV-550 Installation, Operation And Maintenance Manual Download Page 1

CRITICAL INSTALLATION WARNINGS

• Install in recreation vehicles only. RV’s are recreation 
vehicles designed as temporary living quarters for 
recreation, camping, or travel use having their own power or 
towed by another vehicle.
• All combustion air must be supplied from outside the RV, 
and all products of combustion must be vented to outside 
the RV.
• DO NOT vent water heater with venting system serving 
another appliance.
• DO NOT vent water heater to an outside enclosed porch 
area.
• Protect building materials from flue gas exhaust.
• Install water heater on an exterior wall, with access door 
opening to outdoors.
• DO NOT modify water heater in any way.
• DO NOT alter water heater for a positive grounding 
system.
• DO NOT HI-POT water heater unless electronic ignition 
system (circuit board) has been disconnected.
• DO NOT use battery charger to supply power to water 
heater even when testing.

Do not install close to opening door or under room slide-out 

where the vent or inlet louvers can be obstructed.

LPG GAS ON DEMAND
WATER HEATER

Model 
RV-550

11 Sunnybrook Drive
Cincinnati, OH. 45237
Phone: 513-641-4446 * 800-934-9690
Fax:      513-641-0733
www.precisiontemp.com

This water heater design has been certified by the Canadian
Standards Association for installation in recreation vehicles. 

This 

water heater is not for use in space heating applications.

SERVICE CALLS & QUESTIONS

Locations and phone numbers of qualified Service Centers can 
be found at our website www.precisiontemp.com or 
call 

800-934-9690 Ext. 109 to obtain service information.

—Do not store or use gasoline or other
flammable vapors and liquids in the 
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS

• Evacuate all persons from the 
vehicle.
• Shut o

ff

 the gas supply at the 

gas container or source.
• Do not touch any electrical 
switch, or use any phone or radio 
in the vehicle.
• Do not start the vehicle’s engine 
or electric generator.
• Contact the nearest gas supplier 
or qualified service technician for 
repairs.
• If you cannot reach a gas 
supplier or qualified service 
technician, contact the nearest fire 
department
• Do not turn on the gas supply 
until the gas leak(s) has been 
repaired.

 Installation and service must be 
performed by a qualified installer, 
service agency, OEM or the gas supplier.

WARNING: If the information in these 

instructions is not followed exactly, a fire or 
explosion may result causing property 
damage, personal injury or loss of life.

Installation, Operation and Maintenance
Effective 1/13

USA and Canada – Follow all applicable state 
and local codes. In the absence of local codes or 
regulations, refer to the current standards of:

Local codes or, in the absence of local 
codes, the National Fuel Gas Code, ANSI 
Z223.1/NFPA 54 and/or CSA B149.1, 
Natural Gas and Propane Installation 
Code.

Local codes or, in the absence of local 
codes, the Standard on Recreational 
Vehicles, NFPA1192 and/or CAN/CSA-
Z240 RV.

CUTOUT Requirements

OEM and Aftermarket – Unit can be installed in 
PrecisionTemp, Suburban and Girard openings. Unit can also 
be installed through the wall from exterior, or prior to erecting 
wall into place at OEM manufacturing facility.
Rough opening: 

14.25” min. - 16.5” max High

 

 

13.5” min - 17.25” max Wide

 

 

17” min Deep

1

Summary of Contents for RV-550

Page 1: ...to obtain service information Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Evacuate all persons from th...

Page 2: ...se holes with no gaps or openings where the line passes through the case All connections must be made using TWO 2 wrenches to avoid twisting and damaging lines Damage voids the Warranty 5 Erect the si...

Page 3: ...up Before making the connections turn the switch to the OFF position PRESSURE RELIEF VALVE THIS VALVE IS A SAFETY COMPONENT AND MUST NOT BE REMOVED FOR ANY REASON OTHER THAN REPLACEMENT This water he...

Page 4: ...showerhead is turned back on Tests have shown that this will not save water and sometimes uses more water than leaving the shower run continuously Winter Operation and Winterizing Water Heater This h...

Page 5: ...XH 2XWOHW 6FUHHQ OXH 7XEH 3UHVVXUH 6ZLWFK ORZHU VVHPEO DQ DVH OXH RRG VVHPEO DVH VVHPEO HDW FKDQJHU 2 3OXJ 2ULILFH WX 2ULILFH WX 2ULILFH WX 3UHVVXUH OERZ 16 6WDQGDUG RRU LW RORU 5HT 16 DUJH RRU LW ROR...

Page 6: ...An open valve can also permit water to bypass heater causing it not to fire There Is No Ignition When Water Is On Power vent is running 1 Be sure the gas valve at the tank is On there is gas in the t...

Page 7: ...le use neglect tampering or other causes not arising from defects in material workmanship This warranty extends to the original owner of the product only and is subject to the following conditions 1 F...

Reviews: