2
SABRE T
•
MODEL PD743 TEMPERATURE METER
EASy SETUP & PROgRAMMINg
The Sabre T temperature meter is easily programmed using
the four front panel buttons. There is only one switch on the
entire meter, there are no jumpers, and no need to ever open
the case.
Front Panel Buttons
User Friendly Menu Structure
To simplify programming, one menu handles all the setup
functions.
•
Press the
Menu
button to enter or exit the Programming
Mode at any time.
•
Press the
Right arrow
button to move to the next digit
during digit programming.
•
Press the
Up arrow
button to scroll through the menus,
decimal point, or to increment the value of a digit.
•
Press the
Enter/Ack
button to access a menu or to
accept a setting.
Menu Structure
The menu consists of the following functions:
Setup
,
Program
, and
Password
. Press the
Menu
button to enter
the Programming Mode then press the
Up
arrow
button to
scroll through the menu.
The
Setup
menu is used to select the input signal and °F
or °C. The
Program
menu is used to calibrate the meter.
The
Password
menu is used to program a password.
The display moves to the next menu after the
Enter/ACK
button is pressed.
Setting Numeric Values
The numeric values are set using the
Right
and
Up
arrow
buttons. Press the
Right
arrow
button to select next digit
and the
Up
arrow
button to increment the digit value.
The digit being changed is displayed brighter than the rest.
Press the
Enter/ACK
button, at any time, to accept a setting
or the
Menu
button to exit without saving the changes.
SIMPLE OPERATION
Look to the Sabre T temperature meter for the key features
you want and don’t worry about getting bogged down in
a confusing array of things you don’t need. The Sabre T
provides all the utility needed to handle your application with
accuracy and simplicity.
Maximum/Minimum Readings
To display the maximum and minimum readings since the
last reset/power-up, use the
Up
arrow
/
Max
button.
QUICK INSTALLATION
The Sabre T is housed in a 1/8 DIN shallow depth case
that is designed for easy installation and servicing. The
extra large front bezel is rated Type 4X, IP65. The mounting
brackets are locked in place to make it easy to mount the
meter in the panel. Removable screw terminal connectors
make for easy and convenient wiring.
Mounting Dimensions
Units: Inch (mm)
3.61
(92)
2.50
(64)
4.68 (119)
1.76 (45)
0.59
(15)
3.2 (81)
2.45
(62)
Notes:
1. Panel cutout required: 1.772 x 3.622 (45 x 92)
2. Panel thickness: 0.040 – 0.250 (1.0 – 6.4)
3. Mounting brackets lock in place for easy mounting