ProtEX-MAX PD8-6310-WM Explosion-Proof NTEP Certified Batch Controller Instruction Manual
18
Connectors Labeling
The connectors’ label, affixed to the controller, shows the location of all connectors available with
requested configuration.
Warning!
Do not connect any equipment other than
Precision Digital’s expansion modules, cables,
or controllers to the RJ45 M-LINK connector.
Otherwise damage will occur to the equipment
and the controller.
Figure 8: Connector Labeling for Fully Loaded PD6310
Power Connections
Power connections are made to a two-terminal connector labeled POWER on Figure 6. The controller will
operate regardless of DC polarity connection. The + and - symbols are only a suggested wiring convention.
Figure 9: Power Connections
AC or DC
POWER
Required External Fuse:
5 A max, 250 V Slow Blow
POWER
+
-