PD2-6262 Helios Large Display Analog Dual-Input Rate/Totalizer Instruction Manual
5
Ordering Information
Standard Models
85-265 VAC Model 12-24 VDC Model
Options Installed
PD2-6262-6H0
PD2-6262-7H0
No Options
PD2-6262-6H7
PD2-6262-7H7
4 relays & 4-20 mA output
Accessories
Model
Description
PDA1011
Dual 4-20 mA expansion module
PDA6260
Pipe Mounting Kit
PDA7485-I
RS-232 to RS-422/485 isolated converter
PDA7485-N
RS-232 to RS-422/485 non-isolated converter
PDA8485-I
USB to RS-422/485 isolated converter
PDA8485-N
USB to RS-422/485 non-isolated converter
PDAPLUG2
Plastic Conduit Plug
PDX6901
Suppressor (snubber): 0.01 µF/470
, 250 VAC
Specifications
Except where noted all specifications apply to operation at +25°C.
General
Display
Main display: 1.8" (46 mm) high, red
LEDs
6 digits per line (-99999 to 999999), with
lead zero blanking
Display
Intensity
Eight user selectable intensity levels
Display
Update Rate
5/second (200 ms)
Display
Assignment
The Upper and Lower displays may be
assigned to show:
One or more rate channels: Channel A
(Ch-A), B (Ch-B), or C (Ch-C)
Toggle between rate channels: Ch-A &
Ch-B, Ch-A & Ch-C, Ch-B & Ch-C, and
Ch-A, Ch-B, & Ch-C
Total or grand total: Ch-A or Ch-B
Rate and total or grand total: Ch-A,
Ch-B
Relay set points
Max and/or min values: Ch-A, Ch-B, or
Ch-C
Toggle between any rate channel &
units
Total and units: Ch-A or Ch-B
Toggle between totals: Ch-A & Ch-B;
Ch-A, Ch-B, and sum of Ch-A and Ch-
B
Modbus input
The lower display may also be set to
show engineering units or be off, with no
display.
Overrange
Display flashes
999999
Underrange
Display flashes
-99999
Programming
Methods
Four programming buttons, digital inputs,
PC and MeterView Pro software, or
Modbus registers.
Noise Filter
Programmable from 2 to 199 (0 will
disable filter)
Filter Bypass
Programmable from 0.1 to 99.9% of
calibrated span
Recalibration
All ranges are calibrated at the factory.
Recalibration is recommended at least
every 12 months.
Max/Min
Display
Max/min readings reached by the process
are stored until reset by the user or until
power to the meter is turned off.
Password
Three programmable passwords restrict
modification of programmed settings.
Pass 1: Allows use of function keys and
digital inputs
Pass 2: Allows use of function keys,
digital inputs and editing set/reset points
Pass 3: Restricts all programming,
function keys, and digital inputs
Total: Prevents resetting the total
manually
Gtotal: Prevents resetting the grand total
manually.
Power
Options
85-265 VAC 50/60 Hz, 90-265 VDC, 20
W max
or
12-24 VDC
10%, 15 W max
Powered over USB for configuration only.