Programmable Function Keys
User Menu (
user
)
The
User
menu allows the user to assign the front
panel function keys F1, F2, and F3, the digital input
F4 (a digital input located on the signal input
connector), and up to eight additional digital inputs to
access most of the menus or to activate certain
functions immediately (e.g. reset max & min, hold
relay states, etc.). This allows the meter to be greatly
customized for use in specialized applications.
Up to eight digital outputs can be assigned to a
number of actions and functions executed by the
meter (i.e. alarms, relay acknowledgement, reset
max, min, or max & min, tare, and reset tare). The
digital outputs can be used to trigger external alarms
or lights to indicate these specific events.
Function Keys & Digital I/O
Available Settings
Refer to the following table for descriptions of each
available function key or digital I/O setting.
Display
Description
Rst Hi
Reset the stored maximum display
values for all channels
Rst Lo
Reset the stored minimum display values
for all channels
Rst HL
Reset the stored maximum & minimum
display values for all channels
relay
Directly access the relay menu
Set 1*
Directly access the set point menu for
relay 1 (*through 8)
Rly d
Disable all relays until a button assigned
to
enable relays
(
Rly E
) is pressed
Rly E
Enable all relays to function as they have
been programmed
O Hold
Hold current relay states as they are until
a button assigned to
enable relays
(
Rly E
) is pressed
d Hold
Hold the current display value
momentarily while the function key or
digital input is active. The process value
will continue to be calculated in the
background.
D AVP
Scrolls values for A, V & P when
activated. Keeps the last value for 10
seconds and then it returns to its
assignment. Values are displayed on
display line 1 and the corresponding
channel and units on display line 2.
Ln1 Hi
Display maximum channel A display
value on line 1
Ln1 Lo
Display minimum channel A display value
on line 1
Ln1 HL
Display maximum & minimum channel A
display values on line 1
Display
Description
Ln2 Hi
Display maximum channel B display
value on line 2
Ln2 Lo
Display minimum Channel B display
value on line 2
Ln2 HL
Display maximum & minimum channel B
display values on line 2
LitHLP
Display maximum power channel P
display value on line 2
Ln2 HP
Display minimum power channel P
display value on line 2
Ln2 HP
Display maximum & minimum power
channel P display values on line 2
F On 1*
Force relay 1 (*through 4) into the on
state. This function is used in conjunction
with a digital input expansion module to
achieve interlock functionality. See
Setting Up the Interlock Relay (Force On)
Feature
on page
Contrl
Directly access the manual control menu
disabl
Disable the selected function key or
digital I/O
AcH
Acknowledge all active relays that are in
a manual operation mode such as auto-
manual or latching
Reset
Directly access the reset menu
nmenu
Mimic the menu button functionality
(digital inputs only)
rigHt
Mimic the right arrow/F1 button
functionality (digital inputs only)
up
Mimic the up arrow/F2 button
functionality (digital inputs only)
Enter
Mimic the enter/F3 button functionality
(digital inputs only)
Alnm 1*
Provide indication when alarm 1
(*through 8) has been triggered (digital
outputs only)