Operation
46
Operation
Selecting triggering process
The fastener driving tool has two triggering processes:
•
Single triggering
•
Contact triggering
With the tool turned on, select the triggering process on the control
panel:
Press "T" (1):
Single
triggering
The blue LED (3) is lit
continuously.
Press "TTT"
(2):
Contact
triggering
The blue LED (3) flashes.
WARNING
Accidental triggering while changing the triggering
setting may result in severe or fatal injuries.
▶
Do not point the fastener driving tool at yourself,
other people or animals.